SECUR01's MTL Data Center

SECUR01's MTL Data Center is located just minutes from the city center. This Tier III facility was the first of its kind in the greater Montreal area and has maintained 100% uptime since its inception in 2009. Its redundant, best-in-class critical infrastructure provides enhanced concurrent maintainability.

CERTIFICATIONS

PCI-DSS

The Payment Card Industry Data Security Standard (PCI DSS) is an information security standard for organizations that handle branded credit cards from the major card schemes.

Uptime TIER III Design

A Tier 3 data center is a location with redundant and dual-powered servers, storage, network links and other IT components. It is one of the most commonly used data center tiers, where IT components are powered with multiple, active and independent sources of power and cooling resources.

SOC 1 Type II

Includes the design and testing of controls to report on the operational effectiveness of controls over a period of time.

CSAE 3416

The CSAE 3416 report (formerly CICA 5970) provides your customers with the assurance your service business is maintaining effective and efficient internal controls related to financial, informational, or security reporting. This examination is the Canadian equivalent of the AICPA SSAE 16 audit compliance standards.

SSAE 18

The acronym "SSAE" stands for Statement on Standards for Attestation Engagements and was developed by the American Institute of Certified Public Accountants (AICPA).

BUILDING & LAND SPECIFICATIONS

SPACE

20,000 sq. ft.

SPACE CONFIGURATION

2 Halls and 1 MW of critical IT load

Number of Floors

One floor of office and infrastructure space

FLOOR LOAD

1750 lbs/rack & 3999 lbs/rack

RECEIVING AREA

Secure receiving area

LOADING DOCK

24/7 access to loading dock

POWER

SERVICE

175 KW IT Power & 400 KW IT Power

DENSITY DESIGN

Up to 15 kW per cab available standard | higher densities available upon request

POWER PROVIDER

Hydro Quebec

UPS

High availability, concurrently maintainable 1 MW N+1 UPS architecture | flexible 2N solution available upon request

BACKUP GENERATORS

Completely redundant 2N electrical distribution

FUEL RUN-TIME

On-site diesel storage providing 48 hours unrefueled operation

CONNECTIVITY

MEET ME ROOM

2 redundant Meet-Me-Rooms

CONNECTIVITY

Network neutral with access to 20+ carriers including AWS Direct Connect, IX Reach, Megaport.In addition, we have fiber and copper cross connects

IP SERVICES

Managed bandwidth with eStruxture managed AS number and IP range

SECURITY

VIDEO

Monitoring with HD security cameras. All footage stored for minimum 45 days

ON-SITE STAFFING

24/7/365 on site security staff, plus MANTRAPS

ACCESS

24/7 access for registered customers dual-layered physical access control card and facial biometrics access control at mantraps

ENVIROMENTAL CONTROLS

COOLING DISTRIBUTION

Hot aisle/cold aisle containment perforated tiles of the subfloor free cooling system

COOLING CAPACITY

Varies based on densities hall level and individual cabinet level cooling solutions available

REDUNDANCY & DESIGN

N+1 mechanical redundancy with a mechanical design based on optimal free cooling (8+ mo/ year)

FIRE PROTECTION

PROTECTION SYSTEM

VESDA system

ON-SITE FIRE SUPRESSION

Novec clean agent fire protection system